Podium
Structural verification of the colonnade connections
- Client
- C.E.V. S.p.A.
- Location
- Jesolo Lido (VE)
- Year
- 2018–2021
- Residential units
- 47
- Column inclination
- 84.9° – 29.5°
SPC's contribution concerns the colonnade that, from the first floor, extends up to the fourth floor, forming the load-bearing system between these levels: the columns have a complex spatial arrangement, with inclinations from the horizontal ranging between 84.9° and 29.5°, and directions never contained within the planes of the reinforced-concrete shear walls they support.
The connections between the inclined columns and the concrete structure — starting capital, bolted column joint, arrival connection — were each verified in the finite element model, to correctly transfer the vertical component of the axial actions to the ground-floor columns, while limiting the bending and shear actions at the top.